کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6145231 1594904 2015 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Prospective evaluation of a protocol for using transabdominal ultrasound to screen for short cervix
ترجمه فارسی عنوان
ارزیابی آینده نگر از یک پروتکل برای استفاده از سونوگرافی ترانس بطنی به منظور نمایش دهانه رحم کوتاه
کلمات کلیدی
غربالگری طول گردن جلوگیری از نارضایتی، سونوگرافی ترانس القایی، سونوگرافی ترانس واژینال،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پزشکی و دندانپزشکی (عمومی)
چکیده انگلیسی

ObjectiveWe sought to evaluate a recently proposed protocol whereby transabdominal ultrasound of the cervix might be used as a prescreen to select women to undergo or to forgo measurement of cervical length via transvaginal ultrasound (CLvag).Study DesignThis was a prospective cohort study. Measurements of cervical length via transabdominal ultrasound (CLabd) and CLvag were made in women with singleton pregnancy during routine obstetrical ultrasound examination at 180/7 to 236/7 weeks of gestation. The transabdominal screen was considered positive if CLabd was ≤36 mm with the maternal bladder full or ≤35 mm with the bladder empty, or adequate imaging of the cervix could not be obtained. Sensitivity, specificity, predictive values, and likelihood ratios of a positive screen to detect a short cervix (CLvag ≤25 mm) were calculated.ResultsAn interim analysis identified several technical problems with CLabd measurements, so the protocol was extensively revised. Under the revised protocol, 1580 women were included. Adequate views of the cervix were obtained via transabdominal imaging in 46% of subjects with the bladder empty and 56% with the bladder full. The correlation between CLabd and CLvag was poor (r = 0.38). Of the 17 patients with a short cervix, 15 had suboptimal transabdominal exams (screen positive) and 2 had CLabd ≤35 mm with bladder empty (screen positive). Sensitivity of the screen was 100% (95% confidence interval, 80.5-100%) but specificity was only 32.2% (95% confidence interval, 29.9-34.6%) and screen positive rate was 66.3%. Several technical problems and limitations of transabdominal imaging of the cervix are shown.ConclusionUsing modern, high-resolution ultrasound equipment, we were unable to adequately image the cervix via transabdominal ultrasound in half the cases. Although we confirmed that a CLabd cutoff value of 35-36 mm is appropriate for detection of short cervix, the technique for measuring CLabd is fraught with technical problems. Practitioners must validate the technique in their own practice before adopting this or similar prescreening protocols. We decided not to adopt this protocol.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: American Journal of Obstetrics and Gynecology - Volume 213, Issue 1, July 2015, Pages 99.e1-99.e13
نویسندگان
, , , , , , ,