کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6198458 1261950 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
ArticleVisual outcomes after femtosecond laser in situ keratomileusis flap complications
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی چشم پزشکی
پیش نمایش صفحه اول مقاله
ArticleVisual outcomes after femtosecond laser in situ keratomileusis flap complications
چکیده انگلیسی

PurposeTo compare visual outcomes in normal and complicated laser in situ keratomileusis (LASIK) flaps constructed with a femtosecond laser.SettingWilford Hall Ambulatory Surgical Center, San Antonio, Texas.DesignRetrospective chart review.MethodsThe main outcome measures were uncorrected distance visual acuity (UDVA) and best-corrected distance visual acuity (CDVA) at 1 month post-surgery, which were compared in patients with and without complications during flap creation.ResultsThis retrospective chart review identified 586 eyes of 293 consecutive patients who had bilateral simultaneous femtosecond LASIK for myopia. A normal flap was attained in 539 (91.8%) of patients. At 1 month postoperatively, the mean UDVA was 20/19.1, and the CDVA was 20/16.8. 3 (0.51%) of patients experienced an incomplete side cut or intraoperative flap tear (the mean 1-month uncorrected distance visual acuity [UDVA] was 20/17.5 and the corrected distance visual acuity [CDVA] was 20/16.9 in both groups). Microstriae were seen in 28 (4.8%) of patients (mean 1-month UDVA, 20/21.7; CDVA, 20/17.4). Diffuse lamellar keratitis appeared in 4 (0.68%) of patients (mean 1-month UDVA, 20/21.7; CDVA, 20/15.6). Epithelial ingrowth developed in 9 (1.5%) of patients (mean 1-month UDVA, 20/18.7; CDVA, 20/16.9). There was no statistically significant difference in UDVA or CDVA at 1 month postoperatively between complicated and uncomplicated flaps (P > .05), and complicated flaps did not lose a statistically significant amount of CDVA or low-contrast acuity (CDVA 5%) compared to preoperative values.ConclusionsIntraoperative and postoperative complications of LASIK flaps created with the femtosecond laser were rare, and their visual outcomes were equivalent to those of normal flaps.Financial DisclosureCharles D. Reilly is a consultant to Alcon Labs and Abbott Medical Optics at present, but was not at the time of the study. For the remaining authors none are declared.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cataract & Refractive Surgery - Volume 41, Issue 11, November 2015, Pages 2487-2492
نویسندگان
, , , , , ,