کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6205607 1265626 2015 4 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sensitivity of the Oxford Foot Model to marker misplacement: A systematic single-case investigation
ترجمه فارسی عنوان
حساسیت مدل پاکس آکسفورد به اشتباه جابجایی نشانگر: یک بررسی یکپارچه سیستماتیک
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


- We undertook a sensitivity analysis of Oxford Foot Model marker misplacement.
- The heel-wand complex had most pronounced effects across all degrees-of-freedom.
- Vertical misplacement of P5M affected sagittal plane, hindfoot-tibia kinematics.
- D5M and P5M affected sagittal plane, forefoot-hindfoot kinematics.

The purpose of this paper was to systematically assess the effect of Oxford Foot Model (OFM) marker misplacement on hindfoot relative to tibia, and forefoot relative to hindfoot kinematic calculations during the stance phase of gait. Marker trajectories were recorded with an 8-camera motion analysis system (Vicon Motion Systems Ltd., UK) and ground reaction forces were recorded from three force platforms (AMTI, USA). A custom built marker cluster consisting of 4 markers in a square arrangement (diagonal distance 2 cm) was used to assess the effect of marker misplacement in the superior, inferior, anterior and posterior direction for the sustentaculum tali (STL), the proximal 1st metatarsal (P1M), distal 5th metatarsal (D5M), proximal 5th metatarsal (P5M) and lateral calcaneus (LCA) markers. In addition manual movement of the heel complex 1 cm superiorly, inferiorly, medially and laterally, and also an alignment error of 10° inversion and 10° eversion was assessed. Clinically meaningful effects of marker misplacement were determined using a threshold indicating the minimal clinically important difference. Misplacement of the heel-wand complex had the most pronounced effect on mean kinematic profiles during the stance phase across all degrees-of-freedom with respect to hindfoot-tibia and forefoot-hindfoot angles. Vertical marker misplacement of the D5M and P5M markers affected the sagittal plane, and to a lesser extent frontal plane, forefoot-hindfoot kinematics. In conclusion, the OFM is highly sensitive to misplacement of the heel-wand complex in all directions and the P5M marker in the vertical direction.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gait & Posture - Volume 42, Issue 3, September 2015, Pages 398-401
نویسندگان
, , ,