کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6206418 1265646 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
The intra-rater reliability and agreement of compensatory stepping thresholds of healthy subjects
ترجمه فارسی عنوان
پایایی درونی و توافق آستانه گام برداشتن افراد سالم
کلمات کلیدی
سقوط، ارزیابی بالینی، تعادل، ثبات، بزرگسالان سالمند،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی


- Young adults responded to three progressive series of treadmill accelerations.
- Subjects were instructed to either try “not to step” or “to take only one step”.
- Anteroposterior single-stepping and multiple-stepping thresholds were identified.
- Lateral single-stepping thresholds were identified.
- Thresholds demonstrated excellent intrarater reliability (ICC (2,1) = 0.87-0.97).

The purpose of this study was to evaluate the test-retest, intra-rater reliability and agreement of compensatory stepping thresholds. A protocol was developed to establish anteroposterior single-stepping thresholds, anteroposterior multiple-stepping thresholds, and lateral single-stepping thresholds. Healthy, young subjects stood on a microprocessor-controlled treadmill, and responded to three series of progressively challenging surface translations. Subjects were instructed to “try not to step” when establishing single-stepping thresholds or “try to take only one step” when establishing multiple-stepping thresholds. Stepping thresholds were defined as the minimum disturbance magnitude that consistently elicited a single or second compensatory step. Thresholds were expressed as the ankle torque necessary to maintain upright posture. Thresholds studied included anterior single-stepping thresholds (τ = 273.0 ± 82.3 N m), posterior single-stepping, thresholds (τ = 235.5 ± 98.0 N m), anterior multiple-stepping thresholds (τ = 977.0 ± 416.3 N m), posterior multiple-stepping thresholds (τ = 701.9 ± 237.5 N m), stability-side lateral single-stepping thresholds (τ = 225.7 ± 77.7 N m), and mobility-side lateral single-stepping thresholds (τ = 236.8 ±  85.4 N m). Based on intraclass correlation coefficients (ICC) and Bland-Altman plots, all thresholds demonstrated excellent reliability (ICC(2,1) = 0.87-0.97) and agreement. These results suggest that compensatory stepping thresholds have sufficient repeatability to be used in clinical and research-related assessments of fall-risk. Additional study is needed to determine the intra- and inter-rater reliabilities and validity of thresholds specific to the patient populations of interest.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gait & Posture - Volume 39, Issue 2, February 2014, Pages 810-815
نویسندگان
, ,