کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6222476 1607457 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Oxygen Saturation Targeting in Preterm Infants Receiving Continuous Positive Airway Pressure
ترجمه فارسی عنوان
هدف قرار گرفتن اشباع اکسیژن در نوزادان نارس، دریافت فشار مثبت فوری مثبت است
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی پریناتولوژی (پزشکی مادر و جنین)، طب اطفال و بهداشت کودک
چکیده انگلیسی

ObjectiveThe precision of oxygen saturation (SpO2) targeting in preterm infants on continuous positive airway pressure (CPAP) is incompletely characterized. We therefore evaluated SpO2 targeting in infants solely receiving CPAP, aiming to describe their SpO2 profile, to document the frequency of prolonged hyperoxia and hypoxia episodes and of fraction of inspired oxygen (FiO2) adjustments, and to explore the relationships with neonatal intensive care unit operational factors.Study designPreterm infants <37 weeks' gestation in 2 neonatal intensive care units were studied if they were receiving CPAP and in supplemental oxygen at the beginning of each 24-hour recording. SpO2, heart rate, and FiO2 were recorded (sampling interval 1-2 seconds). We measured the proportion of time spent in predefined SpO2 ranges, the frequency of prolonged episodes (≥30 seconds) of SpO2 deviation, and the effect of operational factors including nurse-patient ratio.ResultsA total of 4034 usable hours of data were recorded from 45 infants of gestation 30 (27-32) weeks (median [IQR]). When requiring supplemental oxygen, infants were in the target SpO2 range (88%-92%) for only 31% (19%-39%) of total recording time, with 48 (6.9-90) episodes per 24 hours of severe hyperoxia (SpO2 ≥98%), and 9.0 (1.6-21) episodes per 24 hours of hypoxia (SpO2 <80%). An increased frequency of prolonged hyperoxia in supplemental oxygen was noted when nurses were each caring for more patients. Adjustments to FiO2 were made 25 (16-41) times per day.ConclusionSpO2 targeting is challenging in preterm infants receiving CPAP support, with a high proportion of time spent outside the target range and frequent prolonged hypoxic and hyperoxic episodes.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Pediatrics - Volume 164, Issue 4, April 2014, Pages 730-736.e1
نویسندگان
, , , , , , , , ,