کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6267703 1614598 2016 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Demonstration and validation of a new pressure-based MRI-safe pain tolerance device
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب (عمومی)
پیش نمایش صفحه اول مقاله
Demonstration and validation of a new pressure-based MRI-safe pain tolerance device
چکیده انگلیسی


- Creation of a novel, MRI-safe, pressure-based pain tolerance device.
- Strong correlation between pain tolerance as assessed by MRI-safe device and as assessed by commercially available algometer (Experiment 1).
- With additional pressure, increased activation in insula, anterior cingulate cortex (Experiment 2).
- Activations found in Experiment 2 were comparable with activations found with other types of pain (e.g., thermal, mechanical).

BackgroundOne of the barriers to studying the behavioral and emotional effects of pain using functional Magnetic Resonance Imaging (fMRI) is the absence of a commercially available, MRI-compatible, pressure-based algometer to elicit pain. The present study sought to address this barrier through creation and validation of a novel MRI-safe apparatus capable of delivering incremental, measurable amounts of pressure inside a scanning bore.New methodWe introduced an MR-safe device used to administer pressure-based pain. To test against a commercially available, MRI-incompatible algometer (AlgoMed), 199 participants reported their pain tolerance for both devices. A second experiment tested the validity of pressure-based pain in an MRI environment by comparing brain activation with established neural networks for pain. 10 participants performed an identical procedure to test for pain tolerance while being scanned in a 7T MRI scanner.ResultsResults support the validity and reliability of our novel device. In Study 1, pain tolerance with this device was strongly correlated with pain tolerance as measured by a commercially available algometer (r = 0.78). In Study 2, this device yielded BOLD activation within the insula (BA 13) and anterior cingulate gyrus (BA 24); as pressure increased, activation in these areas parametrically increased.Comparison with existing methodThese findings correspond to other studies using thermal, electrical, or mechanical pain applications. Behavioral and functional data demonstrate that this new device is a valid method of administering pressure-related pain in MRI environments.ConclusionsOur novel MRI-safe device is a valid instrument to measure and administer pressure-based pain.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Neuroscience Methods - Volume 271, 15 September 2016, Pages 160-168
نویسندگان
, , , , , , , , , ,