کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6268498 1614636 2014 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Basic NeuroscienceBallistocardiogram artifact removal with a reference layer and standard EEG cap
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب (عمومی)
پیش نمایش صفحه اول مقاله
Basic NeuroscienceBallistocardiogram artifact removal with a reference layer and standard EEG cap
چکیده انگلیسی


- A method based on BCG reference layer (BRL) is used to remove BCG artifacts.
- Both reference and EEG signals are recorded with a standard EEG cap.
- The BRL effectively suppresses BCG artifacts and retrieves EEG signals.
- The recovery of EEG signal is higher than the traditional method by up to 2-fold.

BackgroundIn simultaneous EEG-fMRI, the EEG recordings are severely contaminated by ballistocardiogram (BCG) artifacts, which are caused by cardiac pulsations. To reconstruct and remove the BCG artifacts, one promising method is to measure the artifacts in the absence of EEG signal by placing a group of electrodes (BCG electrodes) on a conductive layer (reference layer) insulated from the scalp. However, current BCG reference layer (BRL) methods either use a customized EEG cap composed of electrode pairs, or need to construct the custom reference layer through additional model-building experiments for each EEG-fMRI experiment. These requirements have limited the versatility and efficiency of BRL. The aim of this study is to propose a more practical and efficient BRL method and compare its performance with the most popular BCG removal method, the optimal basis sets (OBS) algorithm.New methodBy designing the reference layer as a permanent and reusable cap, the new BRL method is able to be used with a standard EEG cap, and no extra experiments and preparations are needed to use the BRL in an EEG-fMRI experiment.ResultsThe BRL method effectively removed the BCG artifacts from both oscillatory and evoked potential scalp recordings and recovered the EEG signal.Comparison with existing methodCompared to the OBS, this new BRL method improved the contrast-to-noise ratios of the alpha-wave, visual, and auditory evoked potential signals by 101%, 76%, and 75%, respectively, employing 160 BCG electrodes. Using only 20 BCG electrodes, the BRL improved the EEG signal by 74%/26%/41%, respectively.ConclusionThe proposed method can substantially improve the EEG signal quality compared with traditional methods.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Neuroscience Methods - Volume 233, 15 August 2014, Pages 137-149
نویسندگان
, , ,