کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6268710 | 1614640 | 2014 | 5 صفحه PDF | دانلود رایگان |
- We acquired the EEG during an auditory selective attention protocol.
- We developed a new index to detect the focus of auditory attention.
- This index takes into account both the electrode location and coherence value.
- The index seemed to be suitable for BCI applications.
BackgroundAuditory selective attention is the human ability of actively focusing in a certain sound stimulus while avoiding all other ones. This ability can be used, for example, in behavioral studies and brain-machine interface.New methodIn this work we developed an objective method - called Spatial Coherence - to detect the side where a subject is focusing attention to. This method takes into consideration the Magnitude Squared Coherence and the topographic distribution of responses among electroencephalogram electrodes. The individuals were stimulated with amplitude-modulated tones binaurally and were oriented to focus attention to only one of the stimuli.ResultsThe results indicate a contralateral modulation of ASSR in the attention condition and are in agreement with prior studies. Furthermore, the best combination of electrodes led to a hit rate of 82% for 5.03 commands per minute.Comparison with existing method(s)Using a similar paradigm, in a recent work, a maximum hit rate of 84.33% was achieved, but with a greater a classification time (20Â s, i.e. 3 commands per minute).ConclusionsIt seems that Spatial Coherence is a useful technique for detecting focus of auditory selective attention.
Journal: Journal of Neuroscience Methods - Volume 229, 30 May 2014, Pages 28-32