کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6269521 1295143 2012 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Clinical NeuroscienceValidity and inter-rater reliability of inertial gait measurements in Parkinson's disease: A pilot study
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب (عمومی)
پیش نمایش صفحه اول مقاله
Clinical NeuroscienceValidity and inter-rater reliability of inertial gait measurements in Parkinson's disease: A pilot study
چکیده انگلیسی

Walking models driven by centre of mass (CoM) data obtained from inertial measurement units (IMU) or optical motion capture systems (OMCS) can be used to objectively measure gait. However current models have only been validated within typical developed adults (TDA). The purpose of this study was to compare the projected CoM movement within Parkinson's disease (PD) measured by an IMU with data collected from an OMCS after which spatio-temporal gait measures were derived using an inverted pendulum model. The inter-rater reliability of spatio-temporal parameters was explored between expert researchers and clinicians using the IMU processed data.Participants walked 10 m with an IMU attached over their centre of mass which was simultaneously recorded by an OMCS. Data was collected on two occasions, each by an expert researcher and clinician.Ten people with PD showed no difference (p = 0.13) for vertical, translatory acceleration, velocity and relative position of the projected centre of mass between IMU and OMCS data. Furthermore no difference (p = 0.18) was found for the derived step time, stride length and walking speed for people with PD.Measurements of step time (p = 0.299), stride length (p = 0.883) and walking speed (p = 0.751) did not differ between experts and clinicians. There was good inter-rater reliability for these parameters (ICC3.1 = 0.979, ICC3.1 = 0.958 and ICC3.1 = 0.978, respectively).The findings are encouraging and support the use of IMUs by clinicians to measure CoM movement in people with PD.

► We validated the temporal and spatial gait measurements within PD by means of IMU recorded data. ► We explored the inter rater reliability between experts and clinicians using the written algorithms. ► IMU data was found to be insignificant for spatial and temporal aspect of gait when comparing to optical motion capture systems. ► Good inter-rater reliability was found between expert and clinician indicating that. ► These measurements can be used in a clinical setting for people suffering from PD.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Neuroscience Methods - Volume 205, Issue 1, 30 March 2012, Pages 177-181
نویسندگان
, , , , ,