کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
642200 1457024 2012 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of local fouling in a pilot-scale submerged hollow-fiber membrane system for drinking water treatment by membrane autopsy
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
Analysis of local fouling in a pilot-scale submerged hollow-fiber membrane system for drinking water treatment by membrane autopsy
چکیده انگلیسی

An analysis of local fouling in a pilot-scale submerged hollow-fiber membrane water treatment system for drinking water production is described in this paper. Membrane fouling was observed by using microscopic techniques with membrane specimen taken at different longitudinal and horizontal positions of a hollow-fiber membrane module. The resistance-in-series model was used to quantify local fouling resistances of membrane samples. Our results show that the recovery of the permeate flux of the hollow-fiber membrane located near the source of aeration was the highest after performing chemical cleaning. The irreversible fouling resistance was the largest for membrane samples taken near the open ends of the fibers, where the local pressure is expected to be highest. These axial features of irreversible fouling resistance were more pronounced at lower suspended solids concentration or higher set-point flux. However, the local aspect of reversible fouling was relatively less pronounced than the one of irreversible fouling. The results obtained from membrane autopsy were explained well by the local fouling phenomenon driven by the profile of local pressure along the fiber length and transient behavior of this profile during membrane operation. In addition, it was concluded that the individual membrane module experiencing more aeration would have a more localized pattern of membrane fouling, suggesting that the local fouling is more significant under relatively less demanding fouling conditions.


► We observed local fouling in pilot-scale, submerged, hollow-fiber membrane system.
► Axial features of fouling are more significant with irreversible fouling than reversible fouling.
► Aeration is not effective to reduce local fouling as it forms near open ends of fiber.
► Local fouling is more pronounced as feed concentration is lower or set-point flux is higher.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Separation and Purification Technology - Volume 95, 19 July 2012, Pages 227–234
نویسندگان
, ,