کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
653634 | 885209 | 2012 | 7 صفحه PDF | دانلود رایگان |

The present study utilizes the three-dimension numerical and experimental methods to investigate the optimum thermal performance of a flat heat pipe-thermal module application in high-end VGA card cooling system, and compares that with a traditional copper metal based plate embedded three 6 mm diameter heat pipe-thermal module under three dissimilar inclination angles of 0°, 90° and 180°. The optimization for the thermal modules researches into various fin material, thickness and gap. Results show that the flat heat pipe-thermal module has the best thermal performance at high power GPU of 180 W and inclination angle of 180°. Simulation results show in good agreement with experimental results within 5%. Therefore, the thermal performance of a flat heat pipe-thermal module can be accurately simulated and analyzed by employed the manner introduced in this paper and is able to cope with the higher heat flux GPU over 62.5 W/cm2 in the future.
Journal: International Communications in Heat and Mass Transfer - Volume 39, Issue 9, November 2012, Pages 1360–1366