کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
654730 | 885265 | 2007 | 10 صفحه PDF | دانلود رایگان |

The results of the heat transfer characteristics and pressure drop in the corrugated channel under constant heat flux are presented in the present study. The test section is the channel with two opposite corrugated plates which all configuration peaks lie in an in-line arrangement. The corrugated plates with three different corrugated tile angles of 20°, 40°, and 60° are tested with the height of the channel of 12.5 mm. The experiments are done for the heat flux and the Reynolds number in the ranges of 0.5–1.2 kW/m2 and 500–1400, respectively. Effect of relevant parameters on the heat transfer characteristics and pressure drop are discussed. Due to the presence of recirculation zones, the corrugated surface has significant effect on the enhancement of heat transfer and pressure drop.
Journal: International Communications in Heat and Mass Transfer - Volume 34, Issue 1, January 2007, Pages 62–71