کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6679730 1428064 2018 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
System-level performance optimization of molten-salt packed-bed thermal energy storage for concentrating solar power
ترجمه فارسی عنوان
بهینه سازی عملکرد سیستم در سطح ذخیره سازی انرژی حرارتی بسته بندی شده بستر ذوب شده به منظور کاهش غلظت انرژی خورشیدی
کلمات کلیدی
غلظت انرژی خورشیدی، ذخیره انرژی حرارتی، تخت بسته بندی شده، درجه حرارت برش، بهینه سازی هزینه،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی
Molten-salt packed-bed thermal energy storage using thermocline technology is more cost-competitive than the conventional two-tank thermal energy storage, due to its integrated design and the employment of a low-cost packed-bed. However, such a storage configuration suffers the main drawback of a low capacity factor when applied to concentrating solar power because of the adoption of conservative cut-off temperatures. The present work evaluates the feasibility of taking less conservative cut-off temperatures to improve the utilization of the packed-bed thermal energy storage from the perspectives of a system-level operation and storage economy. The investigations are carried out on two levels. The first-level investigation reveals the effects of both the charging and discharging cut-off temperature on the thermal performance of the packed-bed thermal energy storage under ideal operating conditions. Three typical packed-bed configurations are involved. The results show that the capacity factor of the packed-bed thermal energy storage increases as the charging cut-off temperature increases and the discharging cut-off temperature decreases, especially for the configurations using latent-heat when the adopted cut-off temperatures jump over the phase change points of the encapsulated phase change materials. The second-level investigation discusses the impacts of different levels of deep charges (using high charging cut-off temperatures) on the scale design of the packed-bed thermal energy storage, the daily operation of the low temperature molten-salt pump (LT-pump) and the central receiver of a 100 MWe conventional concentrating solar power tower plant. The results indicate that a deeper charge operation is always accompanied with a smaller required packed-bed size as well as a higher required delivery capacity and higher pressure head of the LT-pump and that it always results in a larger daily pumping consumption, a higher peak inlet temperature ramping rate and a higher receiver pressure drop. The maximum allowable charging cut-off temperature is identified to be 500 °C for each packed-bed configuration, according to the operating limitations on the pump and receiver. Moreover, a cost analysis is carried out to obtain the optimum charging cut-off temperature for each packed-bed configuration. The obtained results show that performing deep charges with the cost-optimized charging cut-off temperatures can effectively improve the cost competitiveness of the molten-salt packed-bed TES integrated into concentrating solar power plants.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 226, 15 September 2018, Pages 225-239
نویسندگان
, , , ,