کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6682331 | 501846 | 2016 | 16 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Characterization of the effects of borehole configuration and interference with long term ground temperature modelling of ground source heat pumps
ترجمه فارسی عنوان
تعیین تأثیر پیکربندی گمانه و تداخل با مدل سازی دمای زمین دمای زمین پمپ های حرارتی منبع
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
پمپ های حرارتی منبع زمین، عدم تعادل حرارتی، درجه حرارت، تنظیمات غشاء،
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
مهندسی انرژی و فناوری های برق
چکیده انگلیسی
Ground source heat pumps (GSHPs) are an environmentally friendly alternative to conventional heating and cooling systems because of their high efficiency and low greenhouse gas emissions. The ground acts as a heat sink/source for the excess/required heat inside a building for cooling and heating modes, respectively. However, imbalance in heating and cooling needs can change ground temperature over the operating duration. This increase/decrease in ground temperature lowers system efficiency and causes the ground to foul-failing to accept or provide more heat. In order to ensure that GSHPs can operate to their designed conditions, thermal modelling is required to simulate the ground temperature during system operation. In addition, the borehole field layout can have a major impact on ground temperature. In this study, four buildings were studied-a hospital, fast-food restaurant, residence, and school, each with varying borehole configurations. Boreholes were modelled in a soil volume using finite-element methods and heating and cooling fluxes were applied to the borehole walls to simulate the GSHP operation. 20Â years of operation were modelled for each building for 2Â ÃÂ 2, 4Â ÃÂ 4, and 2Â ÃÂ 8 borehole configurations. Results indicate that the borehole separation distance of 6Â m, recommended by ASHRAE, is not always sufficient to prevent borehole thermal interactions. Benefits of using a 2Â ÃÂ 8 configuration as opposed to a 4Â ÃÂ 4 configuration, which can be observed because of the larger perimeter it provides for heat to dissipate to surrounding soil were quantified. This study indicates that it is important to carefully consider ground temperature during the operation of a GSHP. Borehole separation distances, layout, and hybridization should be studied to alleviate ground fouling problems.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 179, 1 October 2016, Pages 1032-1047
Journal: Applied Energy - Volume 179, 1 October 2016, Pages 1032-1047
نویسندگان
Ying Lam E. Law, Seth B. Dworkin,