کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6688606 501887 2015 15 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Feasibility analysis of using abandoned salt caverns for large-scale underground energy storage in China
ترجمه فارسی عنوان
تجزیه و تحلیل امکان استفاده از غارهای نمکی رها شده برای ذخیره سازی انرژی زیرزمینی در مقیاس بزرگ در چین
کلمات کلیدی
ذخیره انرژی، ذخیره سازی زیرزمینی گاز، غار نمکی رها شده، شبیه سازی عددی، ثبات، نظارت بر زمینه،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی مهندسی انرژی و فناوری های برق
چکیده انگلیسی
Rock salt in China is primarily bedded salt, usually composed of many thin salt layers and interlayers (e.g. anhydrite, mudstone, and glauberite). Thus, the feasibility analysis of abandoned salt caverns located in salt beds to be used as Underground Gas Storage (UGS) facilities is full of challenges. In this paper, we introduce the feasibility analysis of China's first salt cavern gas storage facility using an abandoned salt cavern. The cavern is located in Jintan city, Jiangsu province, China. The mechanical properties and permeability of the bedded salts are obtained by experiments. Based on the results of the analyses, it appears to be quite feasible to convert the abandoned salt caverns of Jintan city to UGS facilities. The stability of the cavern is evaluated by the 3D geomechanical numerical simulations, and the operating parameters are proposed accordingly. Results indicate that the maximum volume shrinkage of the cavern is less than 25% and the maximum deformations are less than 2% of the caverns' maximum diameters after operating for 20 years. It is recommended that the weighted average internal gas pressure be maintained as 11 MPa to control the extent of the plastic zones to a safe level. Safety factors decrease with operating time, especially those of the interface between rock salt and mudstone layers decrease significantly. Effective strain is generally greater than 2%, and locally is greater than 3% after operating 20 years. The maximum pressure drop rate should be kept to less than 0.55 MPa/day. Based on above proposed parameters, China's first salt cavern gas storage facilities were completed, and gas was first injected, in 2007. To check the status of the caverns after operating for 6 years, the volumes of the caverns were measured in 2013 by Sonar under working conditions. Measurement results show that the cavern shapes did not change much, and that volume shrinkages were less than 2%. Comprehensive results show that the feasibility analysis method proposed in this paper is reliable.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Energy - Volume 137, 1 January 2015, Pages 467-481
نویسندگان
, , , , , , , , ,