کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6727156 | 1428915 | 2018 | 26 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Thermal energy storage tank sizing for biomass boiler heating systems using process dynamic simulation
ترجمه فارسی عنوان
اندازه گیری مخزن ذخیره انرژی برای سیستم های گرمایش دیگ بخار با استفاده از شبیه سازی پویایی روند
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
مخزن ذخیره انرژی حرارتی، بهینه سازی، شبیه سازی پویایی فرآیند،
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی انرژی
انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
A novel methodology for optimizing thermal storage for biomass boiler heating systems is presented in this paper. Biomass boiler heating systems have gradually gained popularity in residential, commercial, and large-scale district heating plants due to the lower carbon footprint of biomass energy. One unanswered question in this field was the size of the thermal energy storage (TES) tank with respect to different boiler capacities and different types of heat demand profiles. Different standards and recommendations (based only on boiler capacities) have been proposed by various organizations around the world with large deviations on the sizing of the TES tank, but without a clear technical basis for these recommendations. These inconsistencies impede the effective design and deployment of biomass boiler heating systems. This study used a dynamic process simulation system based on field data from a 25-kW wood pellet boiler with radiant floor heating. By running the simulation for different boiler capacities (N) and different types of heat demand profiles (i.e. low, medium, high, intermittent, and variable), the optimum TES tank volume can be estimated by evaluating the TES tank discharge efficiency, boiler on-time, boiler off-time, and maximum boiler output temperature. Linear correlations between optimum TES tank volume and boiler nominal capacity for different types of heat demand profiles were obtained. The results showed that the medium building heat demand (45% N) required the smallest TES tank volume while intermittent building demand requires the largest. High building demand (60% N) generates the highest TES tank discharge efficiency (up to 99%) but also requires large storage volume. From the economic point of view, it is recommended to size the thermal energy storage system such that the average building heat demand is around 45% of boiler nominal capacity.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy and Buildings - Volume 175, 15 September 2018, Pages 199-207
Journal: Energy and Buildings - Volume 175, 15 September 2018, Pages 199-207
نویسندگان
Wang Kui, Marco A. Satyro, Ross Taylor, Philip K. Hopke,