کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | ترجمه فارسی | نسخه تمام متن |
---|---|---|---|---|---|
6751058 | 1430688 | 2018 | 11 صفحه PDF | سفارش دهید | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Structural response of unprotected and protected slim floors in fire
ترجمه فارسی عنوان
پاسخ ساختاری طبقه های محافظت نشده و محافظت شده در آتش سوزی
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
سفارش ترجمه تخصصی
با تضمین قیمت و کیفیت
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی عمران و سازه
چکیده انگلیسی
Slim floor systems are a latest addition to the existing construction types and are currently being used for various construction purposes. Preference of slim floors over traditional composite floors is due to their ease of construction, when combined with steel decking. Considerable amount experimental work on fire response of slim floors has been conducted since 1980s. Though, these floors offer a better fire resistance, however, fire protection materials including intumescent coatings are often used in situations where a higher fire resistance is desired. Fire tests have also been conducted to analyse the performance of intumescent coating applied on steel elements as a protection material. This study presents a finite element analysis approach to model the behaviour of unprotected and protected slim floors in fire. Initially, FE analysis has been performed to model the thermo-mechanical behaviour of unprotected slim floors and results obtained have been verified against the reported test data. In the middle part, thermal behaviour of an intumescent coating, applied on a steel element as a fire protection, has been modelled and verified. The verified models have finally been combined to perform thermo-mechanical analysis for slim floors protected with intumescent coating. Results show that the protected slim floors offer a higher fire resistance as the temperature of the steel section remains within 400 °C even after 60-minute standard fire exposure. Lower temperatures in steel result in lesser reductions of strength and stiffness, hence, the protected slim floors undergo lesser deflections and offer higher fire resistance.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Constructional Steel Research - Volume 142, March 2018, Pages 44-54
Journal: Journal of Constructional Steel Research - Volume 142, March 2018, Pages 44-54
نویسندگان
Naveed Alam, Ali Nadjai, Faris Ali, Walid Nadjai,
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
سفارش ترجمه تخصصی
با تضمین قیمت و کیفیت