Effect of negative potential on the extent of PID degradation in photovoltaic power plant in a real operation mode
موضوعات مرتبط
مهندسی و علوم پایه مهندسی کامپیوتر سخت افزارها و معماری
پیش نمایش صفحه اول مقاله
Effect of negative potential on the extent of PID degradation in photovoltaic power plant in a real operation mode
چکیده انگلیسی
This paper deals with Potential Induced Degradation (PID) of p-type monocrystalline PV modules (Evergreen) from a photovoltaic power plant that has been in operation mode for 7 years. Within the PV module affected by the PID degradation, the effect of the electric field on individual PV cells is studied. The distribution of the electric field was simulated by SolidWorks software. The results show a random distribution of affected PV cells not related to the size and distribution of the electric field intensity. Furthermore, the dependencies of negative voltage potential on the range of PID degradation of individual PV modules located in the negative pole of the PV string is made. From measured current voltage characteristics (measured at STC), it is evident that the value of negative voltage potential is not directly proportional to the PID occurrence. These results are supplemented by electroluminescence images which confirm this finding.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microelectronics Reliability - Volume 85, June 2018, Pages 12-18