کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7208951 | 1469113 | 2014 | 13 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Bone remodelling around cementless composite acetabular components: The effects of implant geometry and implant-bone interfacial conditions
ترجمه فارسی عنوان
بازسازی استخوان در اطراف اجزای استاپولای مرکب کامپوزیت بدون سیم: اثرات هندسه ایمپلنت و شرایط اینترفیس ایمپلنت استخوان
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
استخوان لگن، پروتز هیپ، جزء استابولیک کامپوزیت، تجزیه و تحلیل عنصر محدود، بازسازی استخوان،
موضوعات مرتبط
مهندسی و علوم پایه
سایر رشته های مهندسی
مهندسی پزشکی
چکیده انگلیسی
Recent developments in acetabular implants suggest flexible, alternative bearing material that may reduce wear and peri-prosthetic bone resorption. The goal of this study was to investigate the deviations in load transfer and the extent of bone remodelling around composite acetabular components having different geometries, material properties and implant-bone interface conditions, using 3-D FE analysis and bone remodelling algorithm. Variation in prosthesis type and implant-bone interface conditions affected peri-prosthetic strain distribution and bone remodelling. Strain shielding was considerably higher for bonded implant-bone interface condition as compared to debonded implant-bone interface condition. The average bone deformation (0.133Â mm) for horseshoe-shaped CFR-PEEK (resembling MITCH PCRTM cup) was very close to that of the intact acetabulum (0.135Â mm) at comparable locations. A reduction in bone density of 21-50% was predicted within the acetabulum for the implant resembling Cambridge cup, having bonded interface. For debonded interface condition, bone density increase of ~55% was observed in the supero-posterior part of acetabulum, whereas bone density reductions were low (1-20%) in other locations. Bone density reductions were considerably less (2-4%) for horseshoe-shaped CFR-PEEK component. Moreover, an increase in bone density of 1-87% was predicted around the acetabulum. Compared to the horseshoe-shaped design, the hemispherical design exacerbated bone resorption. Results indicated that the thickness of the acetabular component played a crucial role in the implant induced bone adaptation. The horseshoe-shaped CFR-PEEK component of 3Â mm thickness seemed a better alternative bearing surface than other designs, with regard to strain shielding, bone deformation and bone remodelling.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 32, April 2014, Pages 257-269
Journal: Journal of the Mechanical Behavior of Biomedical Materials - Volume 32, April 2014, Pages 257-269
نویسندگان
Rajesh Ghosh, Sanjay Gupta,