کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
727708 892792 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Evaluation of moment arm length and fulcrum sensitivity limit in a 10 N·m dead weight torque standard machine
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
Evaluation of moment arm length and fulcrum sensitivity limit in a 10 N·m dead weight torque standard machine
چکیده انگلیسی

Many torque tools, such as torque wrenches and torque screwdrivers, as well as torque measuring devices (TMDs) with a rated capacity of less than 5 N·m are being widely used in industry. Thus, a small-rated-capacity torque standard has to be established as soon as possible. A 10 N·m dead weight torque standard machine (10 N·m DWTSM) has been under development since 2006 at the National Metrology Institute of Japan (NMIJ), part of the National Institute of Advanced Industrial Science and Technology (AIST). Characteristically, the main parts of the moment arm are made of low thermal-expansion alloy (Super INVAR), and an aerostatic bearing is employed as the fulcrum supporting the moment arm to minimize rotational friction. The moment arm was evaluated with regard to the coefficient of thermal expansion (CTE), the lengths measured by a 3D coordinate measurement machine (CMM), and temperature correction realized by measuring the moment arm temperature. The sensitivity limit of the fulcrum in the 10 N·m DWTSM was also estimated. As a result, the apparent overall CTE of the moment arm was 1.06 × 10−6 K−1, and the expanded uncertainty was 2.24 × 10−9 K−1 (k = 2). The results of the CMM measurement were a right-hand side length of 510.2773 mm and a left-hand side length of 510.2657 mm, with a relative expanded uncertainty of 4.0 × 10−5 (k = 2). The moment arm temperature increased by approximately 0.6 K during the ordinary calibration process. The corresponding change in the lengths of the moment arm was estimated to be approximately 0.3 μm, which is considered to be sufficiently small compared with the expanded uncertainty of the lengths of the moment arm. The fulcrum of the 10 N·m DWTSM was found to have sufficient sensitivity under three conditions: without the weight loading components, with the weight loading components, and with loaded weights. In particular, the fulcrum had sufficient sensitivity of at least 0.5 mg when weights of 100 g were loaded on both 5th stages in the weight loading components to generate a radial load equivalent to 1 N·m.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 43, Issue 10, December 2010, Pages 1318–1326
نویسندگان
, , ,