Experimental evaluation of a distributed Brillouin sensing system for measuring extensional and shear deformation in rock
ترجمه فارسی عنوان
ارزیابی تجربی یک سیستم سنجش بریلوئین توزیع شده برای اندازه گیری تغییر شکل اصطکاکی و برشی در سنگ
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
چکیده انگلیسی


• The base noise level for DiTeSt was evaluated as almost ±75 με.
• The linear correlation between frequency and strain was refined.
• The short length event was studied in detail through Brillouin gain spectrum.
• All strained lengths above half spatial resolution was responsive to changes.
• Frequency change showed a parabolic variation with shear displacement.

Distributed Brillouin sensing systems (DBSs) have growing applications in engineering and are attracting attention in the field of underground structures, including mining. The capability for continuous measurements of strain over large distances makes DBSs a promising monitoring approach for understanding deformation field evolution within a rock mass, particularly when the sensor is installed away from excavation damaged zone (EDZ). A purpose-built fiber optic sensing cable, a vital component of DBSs, was assessed in laboratory conditions.A test program was performed to observe DBSs response to various perturbations including strain and joint movements, including opening and shearing of joints. These tests included assessment of the strain-free cable response and the application of extensional and lateral displacement to various sensing cable lengths (strained lengths), from 1 m down to 1 cm. Furthermore, tests were done to evaluate the time-dependent behavior of the cable and to observe the effect of strain transfer using a soft host material (e.g. a soft grout) under lateral displacement.The noise level of the DBSs range was ±77 με, determined through repeated measurements on an unstrained cable. Stretching test results showed a clear linear correlation between applied strain and Brillouin frequency shift change for all strained lengths above half the spatial resolution of the DBSs. However, for strained lengths shorter than half the spatial resolution, no strain response was measurable and this is due to the applied internal signal processing of the DBSs to detect peak Brillouin gain spectrum and noise level. The stability with time of the measurements was excellent for test periods up to 15 h.Lateral displacement test results showed a less consistent response compared to tension tests for a given applied displacement. Although the Brillouin frequency shift change is correlated linearly with the applied displacement in tension, it shows a parabolic variation with lateral displacement. Moreover, the registered frequency response (correlated with strain) of the system decreased significantly when the sensing cable was embedded in a sand-filled tube compared with direct cable displacement.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 77, January 2016, Pages 54–66
نویسندگان
, , , ,