کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
730281 | 1461537 | 2014 | 14 صفحه PDF | دانلود رایگان |
• A robust dynamic reconstruction model is presented for ECT reconstruction.
• An objective functional is proposed for modeling the image reconstruction problem.
• An iteration scheme is developed for solving the proposed objective functional.
• The feasibility of the proposed algorithm is numerically validated.
Electrical capacitance tomography (ECT) is considered as a promising visualization measurement technique, in which reconstructing high-quality images is crucial for real applications. In this paper, a robust dynamic reconstruction model, which incorporates the ECT measurement information and the dynamic evolution information of a dynamic object, is presented. Under the considerations of the low rank property of an ECT image and the inaccuracies on the sensitivity matrix, the reconstruction model and the measurement data, an objective functional that fuses the ECT measurement information, the dynamic evolution information of a dynamic object, the spatial constraint, the temporal constraint and the low rank constraint is proposed. An iteration scheme that integrates the advantages of the fast composite splitting (FCS) algorithm is developed for solving the proposed objective functional. Numerical simulations are implemented to validate the feasibility of the proposed algorithm.
Journal: Measurement - Volume 50, April 2014, Pages 305–318