کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
730590 892987 2009 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Enhanced reflectometry measurements of permittivities and levels in layered petrochemical liquids using an “in-situ” coaxial probe
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
Enhanced reflectometry measurements of permittivities and levels in layered petrochemical liquids using an “in-situ” coaxial probe
چکیده انگلیسی

Measurement and control of the fluid parameters play a very important role in industry applications such as in the petrochemical industrial processing, where there is an increasing demand for real-time determination of dielectric parameters in relation to the product quality. Furthermore, in such a context, additional stringent requirements frequently deal with the spatial localization of non-miscible-layered liquids, like water layers often present in the bottom of tanks during the refinery industrial processing. Recently, reflectometry has become a very attractive method for monitoring applications, thanks to its accuracy and flexibility performance. In this paper, the design of a suitable probe configuration and an associated calibration structure, both leading to an optimal experimental set-up for practical reflectometry measurements in petrochemical industrial applications, are illustrated. Moreover, starting from frequency-domain reflectometry data, a robust optimization procedure is implemented and experimentally tested, thus allowing the accurate evaluation of the frequency-dependent dielectric properties and of multiple levels in different stratified liquids.Results derived through the simple time-domain technique are compared with those achieved through two different frequency-domain approaches, involving the Fast Fourier Transformation (FFT) of time-domain reflectometry (TDR) data and direct vector network analyzer (VNA) measurements, respectively. It is demonstrated that the frequency-domain approaches can significantly enhance the measurement accuracy, allowing the estimation of fuel level with an uncertainty lower than 0.5 mm. Furthermore, it is also shown that a low-cost TDR system, combined with an appropriate FFT-based algorithm, can be successfully adopted for the simultaneous measurement of permittivity and levels, without substantially affecting the measurement accuracy performance when compared to the direct frequency-domain VNA measurements.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 42, Issue 5, June 2009, Pages 685–696
نویسندگان
, , ,