Correction of temperature dependency of a standard; case-study – magnetic flux density standard
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی کنترل و سیستم های مهندسی
پیش نمایش صفحه اول مقاله
Correction of temperature dependency of a standard; case-study – magnetic flux density standard
چکیده انگلیسی

Temperature dependence of measuring instruments represents one of the most influential error sources in measurement of most physical quantities. There are several methods of reducing or cancelling substantial temperature influence on instruments.In this paper we are describing a calculative correction method in the field of precision magnetic flux density measurements, which involves mathematical correction of the instrument properties. For dc magnetic fields under 5 mT, nuclear magnetic resonance (NMR) measurements are both impractical and time-consuming and in some environments even impossible. To avoid complex NMR measurements, field coils as magnetic flux density transfer standards are often used. A method for correction of an air-cored field coil’s coil-constant in order to take into account its temperature dependence is presented. As a result, instead of a complex NMR measurement only a simple current and temperature measurement were needed to calculate the generated magnetic flux density with relative uncertainty of 0.025%.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Measurement - Volume 40, Issues 9–10, November–December 2007, Pages 913–918
نویسندگان
, ,