کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
742509 894315 2015 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Influence of hydrophobization of the polyazulene ion-to-electron transducer on the potential stability of calcium-selective solid-contact electrodes
ترجمه فارسی عنوان
تأثیر هیدروفوبیزاسیون مبدل یون الکترونی پلیآازولن بر پایداری بالقوه الکترودهای تماس مستقیم با کلسیم انتخابی
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


• We report here the use of electrochemically prepared polyazulene (PAz) as the ion-to-electron transducer material in calcium-selective solid-contact ion-selective electrodes (SC-ISEs). Polarization of the PAz solid-contact layer was introduced to achieve a more hydrophobic transducer surface. The hyphenated FTIR-ATR and potentiometric technique has been used to study the influence of the hydrophobization of the PAz transducer layer on the potential stability of the SC-ISEs.

We introduce here electrosynthesized polyazulene (PAz) as a new ion-to-electron transducer material in solid-contact ion-selective electrodes (SC-ISEs). It is shown that the neutral form of PAz possesses high hydrophobicity (water contact angle: 126 ± 14°) due to its aromatic carbon structure. This makes PAz attractive as a solid-contact (SC) material in SC-ISEs in combination with its high redox capacitance which is three times higher than for PEDOT-PSS. We have studied the electrochemical stability of PAz in direct contact with aqueous electrolyte solutions and applied it as the SC layer buried under a calcium-selective plasticized poly(vinyl chloride) ion-selective membrane (ISM). It is demonstrated that the hydrophobization of the PAz solid-contact at E ≤ 0.2 V significantly improved the potential stability of the calcium-selective SC-ISEs which showed a potential drift of only 0.5 mV h−1 when the ISMs were for the first time contacted with 0.1 M CaCl2 for 24 h. Simultaneous determination of the potential stability and the water uptake with the FTIR-ATR spectroscopy could not clearly prove the correlation between low water content at the PAz/substrate interface and the good potential stability obtained with the pre-hydrophobized SC-ISEs. This is due to the relatively uneven surface morphology of the PAz film making the evanescent standing wave of the IR beam to sense water not only in the PAz transducer layer, but also in the ISM. Hence, it is not possible to distinguish between the distribution of water in the ISM and the PAz solid-contact layer. The new SC material presented here was also characterized with cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Sensors and Actuators B: Chemical - Volume 207, Part B, February 2015, Pages 918–925
نویسندگان
, , , ,