کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
743269 | 894348 | 2009 | 6 صفحه PDF | دانلود رایگان |

This paper reports on new GaN sensors using a Pd-mixture-Pd triple-layer sensing structure to enhance their sensitivity to hydrogen at the tens of ppm level. The proposed hydrogen sensor biased with a constant voltage produced relatively high sensing responses of ∼4.84 × 105% at 10,100 ppm and ∼8.7 × 104% at 49.1 ppm H2 in N2. The corresponding barrier height variations are calculated to be 220 and 168 mV. When the sensor is biased by a constant current with maximum power consumption of 0.4 mW, a sensing voltage as an output signal showed a voltage shift of more than 17 V (the highest value ever reported) at 49.1 ppm H2 in N2. By comparison to Pd-deposited GaN sensors, the improvement in static-state performance is likely attributed to double dipole layers formed individually at the Pd–GaN interface and inside the mixture. Moreover, voltage transient response and current transient response to various hydrogen-containing gases were experimentally studied. The new finding is that the former response time is shorter than the latter one.
Journal: Sensors and Actuators B: Chemical - Volume 141, Issue 2, 7 September 2009, Pages 532–537