کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7530365 1487407 2018 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-dimensional biomechanical thumb model for pipetting
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی صنعتی و تولید
پیش نمایش صفحه اول مقاله
Two-dimensional biomechanical thumb model for pipetting
چکیده انگلیسی
Manual pipetting imposes repetitive movements, high force, and awkward postures on the thumb, fingers, and wrist, increasing the risk of musculoskeletal injuries. The purpose of this study is to provide a linear regression model to estimate the optimal pipetting grip height based on the two-dimensional biomechanical static thumb model developed in this study. This biomechanical static thumb model uses hand anatomy and static equilibrium conditions to estimate internal tendon forces against a given external force. Based on the model, we conclude that the optimal grip height is 3 cm in males and 2 cm in females in terms of grip strength and force efficiency. In addition, the model is validated by RMS EMG data from correlation analysis between the predicted internal tendon forces, with RMS EMG values of 0.65 for Flexor Pollicis Longus, 0.57 for Flexor Pollicis Brevis, and 0.61 for Adductor Pollicis.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Industrial Ergonomics - Volume 68, November 2018, Pages 165-175
نویسندگان
, ,