کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
761382 | 896625 | 2011 | 7 صفحه PDF | دانلود رایگان |
![عکس صفحه اول مقاله: Temperature reduction in attic and ceiling via insulation of several passive roof designs Temperature reduction in attic and ceiling via insulation of several passive roof designs](/preview/png/761382.png)
High ambient temperatures coupled with high humidity lead to uncomfortable conditions that are non-conducive for human comfort and productivity. Heat transmission through the roof could be reduced by providing insulation in the attic under the roof or above the ceiling. A roof solar collector could provide both ventilation and cooling in the attic. Several laboratory sized units of passive roof designs were constructed and tested side-by-side under outdoor conditions to obtain temperature data of the roof, attic and ceiling in order to compare their performances.
Research highlights
► Six passive roof designs were tested simultaneously outdoors.
► Roof, attic and ceiling temperatures were determined.
► Solar collector roof design provided the coolest attic and ceiling.
► Placing insulation under roof is preferred to above ceiling.
Journal: Energy Conversion and Management - Volume 52, Issue 6, June 2011, Pages 2405–2411