کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
763816 | 1462878 | 2014 | 8 صفحه PDF | دانلود رایگان |
• Evacuated solar collector (ETC) with a heat shield had better thermal performance.
• Efficiency of ETC with a heat shield is 54.70% at inlet temperature 123.9 °C.
• 31.49% higher than efficiency of ETC without a heat shield at this temperature.
• Heat loss coefficients of ETC with a heat shield was 1.86 W/(m2 K).
• A 50.80% improvement in heat loss reduced compared to ETC without a heat shield.
Experimental performance evaluation and comparative analyses based on heat extraction of direct-flow coaxial evacuated-tube solar collectors with and without heat shields are presented in this paper. A test system to evaluate the thermal performance of medium-temperature solar collectors was developed. The experimental analysis shows the evacuated-tube solar collector performed better with a heat shield, especially at higher working temperatures. The collection efficiency of the solar collector with a heat shield was 54.70% at the highest inlet temperature of 123.9 °C during the test period, which is 31.49% higher than for the solar collector without a heat shield. The calculated heat-loss coefficient for the evacuated-tube solar collector with a heat shield was 1.86 W/(m2 K), which is an improvement of 50.80% compared with that of the collector without a heat shield.
Collection efficiency plots and linear characterization of evacuated tube solar collector with a heat shield (ETC-HS) and evacuated tube solar collector without a heat shield (ETC-NHS)Figure optionsDownload as PowerPoint slide
Journal: Energy Conversion and Management - Volume 84, August 2014, Pages 80–87