کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
7641602 | 1494868 | 2016 | 28 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Inhibition of rhodamine B-ferricyanide chemiluminescence by Au nanoparticles toward the sensitive determination of mercury (II) ions
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
شیمی
شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Inhibition of rhodamine B-ferricyanide chemiluminescence by Au nanoparticles toward the sensitive determination of mercury (II) ions Inhibition of rhodamine B-ferricyanide chemiluminescence by Au nanoparticles toward the sensitive determination of mercury (II) ions](/preview/png/7641602.png)
چکیده انگلیسی
A new high sensitive, selective, and simple method based on the inhibited effect of gold nanoparticles (Au NPs) on rhodamine B (RB)-ferricyanide (Fe(CN)63 â) chemiluminescence (CL) system has been developed for the determination of Hg2 + in environmental samples. This study is the analytical exploiting of Au NPs inhibiting effect on CL system. RB-Fe(CN)63 â causes a high emission intensity in alkaline condition but undergoes an intense extinction in the presence of Au NPs. This decreasing effect can be attributed to the energy transfer and collisions between RB molecules and Au NPs. Moreover, it is observed that the CL intensity is gradually restored in the presence of mercury (II) due to RB molecules release from the surfaces of Au NPs. Based on this effect, sensitive, and selective turn-on CL assay was developed for the determination of Hg2 +. Under the optimized conditions, CL calibration curve was drawn as a function of Hg2 + concentration, which is linear over the range of 0.013-4.67 μg Lâ 1 (0.067-23.3 nmol Lâ 1) with limit of detection (3s) and quantification (10s) of 5.42 and 18 ng Lâ 1, respectively. The relative standard deviations (RSD%, n = 5) were about 0.7-2.1% for the different concentrations of Hg2 +. The presented assay was satisfactorily applied to the quantification of Hg2 + in the environmental (tap, rain, and river) water samples, which shows good sensitivity and reliability in comparison with the other nanoparticle-based methods; the recoveries were 97-102%.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Microchemical Journal - Volume 126, May 2016, Pages 326-331
Journal: Microchemical Journal - Volume 126, May 2016, Pages 326-331
نویسندگان
Behrouz Vahid, Javad Hassanzadeh, Jafar Abolhasani, Behzad Khodakarami,