کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
7662 559 2011 12 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Discontinuities in the human bone–PDL–cementum complex
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بیو مهندسی (مهندسی زیستی)
پیش نمایش صفحه اول مقاله
Discontinuities in the human bone–PDL–cementum complex
چکیده انگلیسی

A naturally graded interface due to functional demands can deviate toward a discontinuous interface, eventually decreasing the functional efficiency of a dynamic joint. It is this characteristic feature in a human bone–tooth fibrous joint bone–PDL–tooth complex that will be discussed through histochemistry, and site-specific high resolution microscopy, micro tomography(Micro XCT™), X-ray fluorescence imaging and wet nanoindentation techniques. Results demonstrated two causes for the occurrence of 5–50 μm narrowed PDL-space: 1) microscopic scalloped regions at the PDL-insertion sites and macro-scale stratified layers of bone with rich basophilic lines, and 2) macroscopic bony protrusions. Narrowed PDL-complexes illustrated patchy appearance of asporin, and when imaged under wet conditions using an atomic force microscope (AFM), demonstrated structural reorganization of the PDL, collagen periodicity, organic-dominant areas at the PDL–cementum and PDL–bone entheses and within cementum and bone. Scanning electron microscopy (SEM) results confirmed AFM results. Despite the narrowed PDL, continuity between PDL and vasculature in endosteal spaces of bone was demonstrated using a Micro XCT™. The higher levels of Ca and P X-ray fluorescence using a microprobe were correlated with higher elastic modulus values of 0.1–1.4 and 0.1–1.2 GPa for PDL–bone and PDL–cementum using wet nanoindentation. The ranges in elastic modulus values for PDL–bone and PDL–cementum entheses in 150–380 μm wide PDL-complex were 0.1–1.0 and 0.1–0.6 GPa. Based on these results we propose that strain amplification at the entheses could be minimized with a gradual change in modulus profile, a characteristic of 150–380 μm wide functional PDL-space. However, a discontinuity in modulus profile, a characteristic of 5–50 μm wide narrowed PDL-space would cause compromised mechanotransduction. The constrictions or narrowed sites within the bone–tooth fibrous joint will become the new “load bearing sites” that eventually could cause direct local fusion of bone with cementum.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biomaterials - Volume 32, Issue 29, October 2011, Pages 7106–7117
نویسندگان
, , , , , ,