کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
766281 897091 2009 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Derating of an induction machine under voltage unbalance combined with over or undervoltages
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
پیش نمایش صفحه اول مقاله
Derating of an induction machine under voltage unbalance combined with over or undervoltages
چکیده انگلیسی

This work deals with the load carrying capacity of an induction cage machine under voltage unbalance combined with over- or undervoltage. The effect of complex voltage unbalance factor (CVUF) angle on the derating factor is taken into consideration. The derating curves obtained with two different methods are compared. The machine efficiency, stator currents and temperature-rise distribution after applying the required derating factor are discussed. The results of experimental investigations and computer calculations are presented for two low-power induction motors of opposite properties. One of them has a comparatively weakly saturated magnetic circuit and is especially exposed to the risk of overheating for undervoltage. The other investigated machine has a comparatively strongly saturated magnetic circuit and is especially exposed to overheating in the conditions of overvoltage.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Energy Conversion and Management - Volume 50, Issue 4, April 2009, Pages 1101–1107
نویسندگان
,