کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
790201 1466427 2014 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental investigation of the refrigerant flow of isobutane (R600a) through adiabatic capillary tubes
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی مکانیک
پیش نمایش صفحه اول مقاله
Experimental investigation of the refrigerant flow of isobutane (R600a) through adiabatic capillary tubes
چکیده انگلیسی


• New experimental data for adiabatic capillary tube flow of R600a is reported.
• The data extends the available data in the literature which consist up to now only in one single source.
• 2 correlations of the literature have been checked if they predict both ours and the already published data.
• The semi-algebraic equation from Hermes et al. (2010) predicts 94% of the data within a ± 10% error band.

Capillary tubes are widely used as expansion device in small scale refrigeration systems. Despite the simple geometry one finds complex physical processes during the throttling in the capillary tube, which were subject of many studies in the last decades. However, there is currently only one source of experimental data for the refrigerant isobutane (R600a) and adiabatic capillary tubes (Melo et al., 1999). In order to close this gap a test rig was built and experimental data in the range of typical small scale refrigeration systems was collected. The measured mass flow rates span from 0.64 kg h−1 to 1.93 kg h−1. Additionally, the effect of critical flows (Choked Flow) is shown by means of an extra performed test. The semi-algebraic equation from Hermes et al. (2010) showed a remarkable level of agreement by predicting 94% of all points within a ±±10% error band.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Refrigeration - Volume 38, February 2014, Pages 275–280
نویسندگان
, ,