Effect of the temperature of different combustion zones in the boiler grate on changes in physical and chemical parameters of bituminous coal and slags
ترجمه فارسی عنوان
اثر دمای مناطق مختلف احتراق در مخزن دیگ بخار بر تغییرات پارامترهای فیزیکی و شیمیایی ذغالسنگ بتمنیم و سرباره
کلمات کلیدی
پارامترهای فیزیکی، پارامترهای شیمیایی، جیوه، رطوبت بویلر، ذغال سنگ بتمنس، سرباره،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی (عمومی)
چکیده انگلیسی
This paper presents the results of a study on the influence of the temperature of characteristic zones of coal combustion in a stoker fired boiler (drying, degassing, and burn-out), on changes in physical and chemical parameters of bituminous coal and slags. This information is important as it helps identify the impact of coal properties on the accumulation of trace elements, primarily mercury, in combustion waste. The study is the continuation of research work on the impact of mercury compounds accumulated in combustion waste on the natural environment (mercury from landfills of slag, and fly ash). Studies were undertaken because no in-depth analysis of the impact of the temperature of particular zones of stoker fired boilers on the physical and chemical parameters of the post-process slag, including mercury content, had been reported in literature. Both of the coals examined, classified as bituminous coal according to the International Classification of Seam Coals and of type 32.1 according to the PN-G-97002:1982 standard, showed an average mercury content of 0.0849 μg/g. In the chemical composition determined for the ash derived from burnt coal, the dominance of SiO2 and Al2O3 over other oxides was found. This feature results in the increase of the softening temperature and ash melting and, therefore, during the combustion of coal tested in a stoker fired boiler, only ash was subjected to the sintering process. Mercury content in the other examined samples taken from various locations of the stoker fired boiler (drying - 32-1050 °C, degassing - 1050-1020 °C, and burn-out - 1020-400 °C) varied from 0.0668 to 0.0009 μg/g and was determined with the use of a LECO atomic absorption spectrometer. The analyses of the elemental composition, performed with the application of XRF spectrometry, for ash obtained from samples collected from different sampling points of the stoker fired boiler showed that the largest concentration of trace elements was observed for the ash derived from the samples collected in the degassing zone (temperature range 1050-850 °C).
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Sustainable Mining - Volume 15, Issue 2, 2016, Pages 73-83
نویسندگان
, ,