کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
815279 | 906325 | 2010 | 4 صفحه PDF | دانلود رایگان |

The surfaces of Ti17 alloy were strengthened by an electric spark treatment (EST), then an ultrasonic surface treatment was used in order to improve the fatigue life. The surface morphology was observed by SEM. The surface residual stress was analyzed by a X-ray diffractometer. Tension-tension fatigue tests were carried out in a HT-100 fatigue testing machine at 350 °C. The results show that the surface roughness and the residual stress are reduced for the specimens after the ultrasonic treatment. The fatigue life of the specimens strengthened by ultrasonic treatments is about twice that of the specimens treated by EST only. The fatigue life of the specimen strengthened by YG8 electrode EST combination with ultrasonic treatment is the longest.
Journal: Rare Metal Materials and Engineering - Volume 39, Issue 12, December 2010, Pages 2091-2094