کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8166013 1526224 2018 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Digital neutron and gamma-ray radiography in high radiation environments with an MCP/Timepix detector
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Digital neutron and gamma-ray radiography in high radiation environments with an MCP/Timepix detector
چکیده انگلیسی
The radiation levels from used nuclear fuel make their post irradiation examination very difficult. Handling material removed from assemblies is almost exclusively performed inside shielded hot cells. Neutron radiography provides a non-destructive option for examining the internal structure, location and integrity of irradiated fuel. This paper addresses the performance and stability of a neutron imaging detector comprised of microchannel plates (MCPs) and a Timepix readout in gamma and neutron radiation environments. The detector is being considered as an alternative to the currently used activation foils and photographic film measurement techniques. The MCP/Timepix detector was used in neutron radiography experiment on a beam line at the Neutron Radiography Reactor (NRAD) at Idaho National Laboratory (INL). The detector was installed ∼17.5 m from the reactor core with a line of sight view to the core, which results in a fast and epithermal neutron spectrum as well as high intensity gamma radiation. The gamma-ray dose rate in the beam line was 812 mSv/hr. Complementary measurements were made using  137Cs and  60Co isotopic sources at gamma dose rates in excess of 6 Sv/hr. The detector functioned normally over several hours in this environment. These conditions are comparable to planned radiography of irradiated nuclear fuel assemblies. Experimental results using ASTM sensitivity and beam purity indicators suggest that a spatial resolution of <100 μm may be possible in neutron radiographic measurements using this detector for studies of irradiated nuclear fuel. Potential radiographic and tomographic applications are discussed. The results of present experiments are not limited to the studies of irradiated fuel assemblies, but rather are relevant to any experiment where imaging needs to be performed in a high radiation environment.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 902, 11 September 2018, Pages 110-116
نویسندگان
, , , , , , , ,