کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8175695 1526363 2014 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Isochronicity corrections for isochronous mass measurements at the HIRFL-CSRe
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Isochronicity corrections for isochronous mass measurements at the HIRFL-CSRe
چکیده انگلیسی
Isochronous Mass Spectrometry (IMS) is a unique experimental method for mass measurement experiments on short-lived nuclei. Mass measurements of 78Kr projectile fragments were performed in HIRFL-CSRe at the Institute of Modern Physics (IMP), Chinese Academy of Sciences. The short-lived secondary beams were produced by bombarding a 15 mm thick beryllium-target in the Radioactive Ion Beam Line (RIBLL2) and were then injected into the CSRe storage ring. The masses of stored ions were measured by employing the IMS technique, which is based on the determination of the ion revolution times. A dedicated time-of-flight (TOF) detector is used for the latter purpose. However, the isochronicity, and thus the mass resolving power, depends on the momentum spread and the transverse emittance of the injected beams, Here, we present the first-order isochronicity optimization, the chromaticity and second-order isochronicity corrections through the modification of the quadrupole and sextupole field strengths. With the help of these corrections, the mass resolution of Δm/m=10−6 can be achieved.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 763, 1 November 2014, Pages 53-57