چکیده انگلیسی
We have evaluated a silicon-strip detector with a 0.18-μm CMOS application specific integrated circuits (ASIC) containing 160 channels for use in photon-counting digital mammography. Measurements were performed at the Elettra light source using monochromatic X-ray beams with different energies and intensities. Energy resolution, ΔE/Ein, was measured to vary between 0.10 and 0.23 in the energy range of 15-40 keV. Pulse pileup has shown little effect on energy resolution.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 749, 11 June 2014, Pages 1-6