کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8180218 1526424 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Monitoring system for a synthesizer at SPring-8 synchrotron radiation facility and obtained results
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Monitoring system for a synthesizer at SPring-8 synchrotron radiation facility and obtained results
چکیده انگلیسی
Beam orbit distortion in all dispersive sections was observed in the SPring-8 storage ring during beam commissioning. In order to confirm the stability of the radio frequency (RF) synthesizer, a monitoring system was developed. The system consists of a frequency counter referenced to a global positioning system (GPS) receiver. With this system, the output of the synthesizer, which uses an external 10 MHz-Rubidium atomic clock with the time accuracy of Δt/t=10−12, is correctly monitored with 11 digits absolute accuracy, verifying that the synthesizer works well. Measurement of the circumference of the SPring-8 storage ring reveals the effect of tidal forces and seasonal temperature variations on beam orbit. To maintain the center axis of photon radiation in experimental beam lines, a beam energy correction is carried out. The frequency of the RF synthesizer is changed every 5 min with 10-digit accuracy. This corresponds to an energy accuracy of ΔE/E=1.16×10−6. The monitoring system for the synthesizer and obtained results are described.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 701, 11 February 2013, Pages 243-248