کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8180228 1526424 2013 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Beam experiments on the RFQ and SFRFQ combined accelerator system
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم ابزار دقیق
پیش نمایش صفحه اول مقاله
Beam experiments on the RFQ and SFRFQ combined accelerator system
چکیده انگلیسی
As an injector for the Separated Function RFQ (SFRFQ) accelerator, the Integral Split Ring Radio Frequency Quadrupole (ISR RFQ) accelerator was upgraded to achieve a higher beam current. The experiments on the RFQ accelerator indicated that the maximum accelerated O+ beam current could exceed 3.2 mA with an energy of 1.03 MeV and energy spread (FWHM) of 3.1%. The resultant beam is then transported through a 1-m-long magnetic triplet and finally accelerated to 1.654 MeV by the SFRFQ cavity. The beam conditions of the RFQ accelerator were carefully optimized to satisfy the requirements of the SFRFQ accelerator, and the combined accelerator was able to deliver 0.53 mA of O+ beam to the end of the beam line, which has sufficiently demonstrated the feasibility of the SFRFQ cavity.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment - Volume 701, 11 February 2013, Pages 273-277
نویسندگان
, , , , , , , , , , ,