کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
818209 1469434 2013 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Design limits for RC slabs strengthened with hybrid FRP-HPC retrofit system
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
Design limits for RC slabs strengthened with hybrid FRP-HPC retrofit system
چکیده انگلیسی
A polymeric hybrid composite system made of high-performance concrete (HPC) and an innovative carbon/epoxy reinforced polymer (CFRP) unidirectional laminates was proposed as a retrofit system to enhance flexural strength and ductility of reinforced concrete (RC) slabs. The effectiveness of the proposed system was confirmed through experimental evaluation of three full-scale one-way slabs having two continuous spans. In this study, the results of the loading tests for the hybrid high-performance retrofit system are presented and discussed. Design limits to derive a flexural failure of a continuous RC slab strengthened with the hybrid retrofit system are extracted. Using the proposed design limits, the procedure of a flexural failure design for a continuous RC slab strengthened with the hybrid retrofit system is demonstrated with numerical examples for two types of the retrofit systems with respect to overlay strength. The flexural failure design limits can be extended for flexural and shear strengthening design with externally bonded FRP to ensure flexure failure for a continuous flexural members.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Composites Part B: Engineering - Volume 51, August 2013, Pages 19-27
نویسندگان
, , , ,