کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
821211 906748 2010 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
High resolution tomographic imaging and modelling of notch tip damage in a laminated composite
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
High resolution tomographic imaging and modelling of notch tip damage in a laminated composite
چکیده انگلیسی

Synchrotron radiation computed tomography (SRCT) has been used to observe in situ damage growth and enable micromechanical damage characterization in [90/0]S carbon fibre–epoxy composite samples loaded in uniaxial tension to stresses ranging from 30% to 90% of the nominal failure stress. A 3-D finite element model has been constructed to predict crack opening displacements and shear displacements in the 0° plies resulting from thermal residual stress imposed during autoclave cure and from the application of mechanical load. Of particular interest is the demonstration of SRCT as a technique to enable direct, in situ, 3-D, non-destructive damage quantification to assist model development and provide model validation. In addition it has been identified that SRCT has the potential for full field analysis of strain re-distributions during damage growth.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Composites Science and Technology - Volume 70, Issue 10, 30 September 2010, Pages 1444–1452
نویسندگان
, , , ,