Damage detection of glass fiber reinforced composites using embedded PVA–carbon nanotube (CNT) fibers
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
Damage detection of glass fiber reinforced composites using embedded PVA–carbon nanotube (CNT) fibers
چکیده انگلیسی

Polyvinyl alcohol–carbon nanotube (PVA–CNT) fibers were embedded in glass fiber reinforced plastic composites and used as strain sensors for damage monitoring of the composite. Sensing of the structural integrity of the composite was made by the in situ measurement of the electrical resistance of the embedded PVA–CNT fiber during the mechanical tests. The multi-functional materials were tested in tensile progressive damage accumulation (PDA) tests. These tests aimed to seek the electrical response of untreated and pre-stretched PVA–CNT fibers with known level of progressively induced damage to the composite. The advantages and disadvantages of each PVA–CNT fiber used as a sensor are analyzed; the electrical resistance readings of the PVA–CNT fibers were correlated with known parameters that express the induced damage of the composite.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Composites Science and Technology - Volume 70, Issue 12, 31 October 2010, Pages 1733–1741