Comparison of day 0 and day 14 dosimetry for permanent prostate implants using stranded seeds
موضوعات مرتبط
مهندسی و علوم پایه فیزیک و نجوم تشعشع
پیش نمایش صفحه اول مقاله
Comparison of day 0 and day 14 dosimetry for permanent prostate implants using stranded seeds
چکیده انگلیسی
Conclusion: The dose to the prostate changed between Days 0 and 14 in most patients, resulting in a change in clinical status (acceptable or unacceptable) in 12 of 28 patients. Profound increases in normal tissue doses may make dose and toxicity correlations using Day 0 dosimetry difficult. No relationship was found between the prostate volume change and D90 change, and, in 11 patients, a paradoxic dosimetric result was noted. A differential z-axis shift of stranded seeds vs. prostate had a greater impact on final dosimetry and dose to critical adjacent tissues than did prostate swelling. These findings challenge the model that swelling is the principal cause of dosimetric changes after implantation. Stranded seeds may have contributed to this outcome. On the basis of these findings, a change in technique to avoid placement of stranded seeds inferior to the prostate apex has been adopted. These results may not apply to implants using single seeds within the prostate.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Radiation Oncology*Biology*Physics - Volume 64, Issue 1, 1 January 2006, Pages 144-150