When the defocus cannot be measured and the wavefront solution set is restricted by a multi-channel, some practical problems exist in the calibration of the noncommon path aberrations of the adaptive optics system. To solve these problems, an evaluation function of phase diversity algorithm is constructed in this paper. We use the method that the estimated aberration and the modulated deformable mirror iterate each other to make up the nonideal measurement environment. Then the ill-pose problem of the solution by phase diversity, produced as relaxing constraints of the diversity defocus on the wavefront solution set, is solved. We have adopted the proposed method to measure the noncommon path aberrations of the adaptive optics system on a 1.23 m telescope. Experimental results demonstrate that wavefront solution is more accurate and the whole imaging quality is improved effectively by using the deformable mirror to compensate the aberration measured.
Journal: Optik - International Journal for Light and Electron Optics - Volume 125, Issue 17, September 2014, Pages 5029–5035