| کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
|---|---|---|---|---|
| 851640 | 909329 | 2011 | 4 صفحه PDF | دانلود رایگان |
In this study, the magnetic field-parameters of a typical saddle-shaped deflection yoke were measured using the dual-coil method developed by the group. The measurement data was processed and analyzed using two methods: 2-variable regression analysis method and 3-variable regression analysis method. The two results were compared with the analytically calculated results, which was used as the reference. It was shown that the data collection range has large impact to the results of H2, H4, and the further away from the central axis the probe is placed, the larger the error is. The errors of H2 and H4 are smaller using the 3-variable regression analysis method as compared with the ones using 2-variable regression method. The 3-variable regression analysis method uses H6 in the process of calculating H2 and H4, which is coincident with the definition of them in the formula of Hy = H0 + H2X2 + H4X4 + H6X6 +⋯.
Journal: Optik - International Journal for Light and Electron Optics - Volume 122, Issue 10, May 2011, Pages 896–899