کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
8555469 1562769 2016 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Analysis of Temperature Variability in Medication Storage Compartments in Emergency Transport Helicopters
ترجمه فارسی عنوان
تجزیه و تحلیل تغییرات دما در بخش های ذخیره سازی دارو در هلیکوپتر حمل و نقل اورژانس
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی طب اورژانس
چکیده انگلیسی
The purpose of this study was to determine whether the temperature in medication storage compartments in air medical helicopters was within United States Pharmacopeia (USP)-defined limits for controlled room temperature. This was a prospective study using data obtained from a continuous temperature monitoring device. A total of 4 monitors were placed within 2 medication storage locations in 2 identical helicopters. The data collection period lasted 2 weeks during the summer and winter seasons. Data retrieved from monitors were compared against USP parameters for proper medication storage. Results documented temperatures outside the acceptable range a majority of the time with temperatures above the high limit during summer and below the low limit during winter. The study determined that compartments used for medication storage frequently fell outside of the range for USP-defined limits for medication storage. Flight programs should monitor storage areas, carefully taking actions to keep medication within defined ranges.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Air Medical Journal - Volume 35, Issue 6, November–December 2016, Pages 360-364