کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
859311 1470757 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Suitability of Pulse Error Models for Time-domain Spectrum Measurements
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
Suitability of Pulse Error Models for Time-domain Spectrum Measurements
چکیده انگلیسی

Measurementsof electromagnetic compatibility properties of electronic systems are inevitable to guarantee the reliability and safety of control or robotic systems. For automation of such measurements time effective TDEMI (Time Domain ElectroMagnetic Interference) devices are used. Their principally new structure with parallel analog input channels followed by fast digital signal processing provides fast EMI spectrum measurements. On the other side it brings the risk of introduction of new unknown error sources caused by differences between transfer characteristics of parallel input channels. A special pulse model of the errors was proposed. Results of the precise simulation pulse model and simplified theoretical pulse model are compared together and with the experimental test on the harmonic input signal.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Procedia Engineering - Volume 69, 2014, Pages 415-422