کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
863417 1470815 2011 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Macroscopic structural behavior on the small-scale PHE prototype under high-temperature test condition
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی (عمومی)
پیش نمایش صفحه اول مقاله
Macroscopic structural behavior on the small-scale PHE prototype under high-temperature test condition
چکیده انگلیسی

PHE (Process Heat Exchanger) is a key component to transfer the high temperature heat generated from a VHTR (Very High Temperature Reactor) to the chemical reaction for massive production of hydrogen. Korea Atomic Energy Research Institute established a small-scale gas loop for the performance test of VHTR components and manufactured a PHE prototype in order to test in the small-scale gas loop. In this study, in order to investigate the macroscopic structural characteristics and behaviour of the PHE prototype under the test condition of the small-scale gas loop, we carried out high-temperature structural analysis modelling, thermal analysis, and an elastic/elastic-plastic structural analysis for the PHE prototype under the loop test conditions as a precedent study prior to the performance test in the small-scale gas loop. The results obtained in this study will be compared with the performance test results in the near future.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Procedia Engineering - Volume 10, 2011, Pages 48-56