کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
873258 910304 2008 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Impact-induced osteochondral fracture in the tibial plateau
موضوعات مرتبط
مهندسی و علوم پایه سایر رشته های مهندسی مهندسی پزشکی
پیش نمایش صفحه اول مقاله
Impact-induced osteochondral fracture in the tibial plateau
چکیده انگلیسی

In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5 mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to obtain 3-D image reconstructions of the cartilage and underlying bone. Cartilage failure upon impact appeared to be characteristically brittle in nature. Impacted cartilage from the region not protected by the meniscus showed a relatively large cavernous disruption with microcrack propagation extending radially into the subchondral bone, while impacted cartilage from beneath the meniscus showed less dramatic surface disruption and with no underlying bone failure.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Biomechanics - Volume 41, Issue 6, 2008, Pages 1236–1242
نویسندگان
, , , ,